day/time
program
PROGRAMMABLETHERMOSTAT
OwnersManual
Model:CP1819
L
Congratulations!
Your new thermostat will provide years of reliable service. By saving energy, your
thermostatwillpayforitselfduringitsfirstseasonofuse.Thanksyouforbuyingour
product!
Please read this manual for complete instructions on installing and operating your
thermostat.Ifyourequirefurtherassistance,pleasefeelfreetocontactus
IMPORTANTINFORMATION
1.Thistherm ostatisdesignedtoworkonthefollowingsystems:
ŸGas–StandingPilot ŸOil–FiredFurnace
ŸGas–ElectronicIgnition ŸSingleStageHeatPumps–
withnoauxiliaryheat
ŸGas–FiredBoilers ŸElectricAirConditioning
ŸGas–MillivoltSystems ŸElectricFurnace
ŸOil–FiredBoilers
This thermostat will NOT control multistage heat pumps or 110/220V baseboard
electricheatingsystems.
2.TemperatureRange
Thisthermostatcanbeprogrammedbetween45˚Fand95˚F(7˚Cand35˚C).However,
it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). “HI” will be
displayed ifthetemperatureishigherthan99˚F(37˚C),and “LO”willbe displayedif
thetemperatureislowerthan30˚F(0˚C).
Thisthermostatwillautomaticallycutoffin Heatmodeifthetemperaturerises above
95˚F (35˚C), and automatically cutoff in Cool mode if the temperature drops below
45˚F(7˚C).
3.CompressorProtection
Thisthermostatprovidesa4minutesdelayaftershuttingoffthecoolingsystembefore
it canbe restarted. This feature will prevent damagetoyour compressorcausedby
rapid cycling. It does not prevent a rapid compressor restart due to short power
outages.
4.BatteryWarning
TwofreshAAalkalinebatteriesshouldprovidewellaboutoneyearofservice.However,
whenthebatteriesbecomedrained,theLowBatteryIndicatorwillflashonthedisplay.
Whenthismessageoccurs, install new alkaline batteries.You have approximately1
minutetochangethebatteriesandkeepthethermostat’sclockandprogramsettings.
Oncethebatterieshavebecometoolowtoensureproperoperation,yoursystemwill
beturnedoff,andthedisplaywillbeclearedexceptforflashingLowBatteryIndicator
ontheLCDdisplay.
CAUTION: When only the Low Battery icon flashes on the display,
thethermostatisshutdown,andyoursystemwillnolongeroperate.
Inthiscondition,thereisnotemperaturecontrolofyourdwelling.
NOTE:Thebacklightwillnotfunctionwhenthethermostatisinlowbatterycondition.
NOTE: Ifyou planto be awayfrom thepremisesover 30 days, we recommendthat
youreplacetheoldbatterieswithnewalkalinebatteriespriortoleaving.
5.Powersupply
Thethermostatshallbepoweredby24VACandwithbatteriesasbackup.
FEATURES
Structureofthermostatandexplanationforthekeypads
h ea tof fcoo l on au to
da y/ti me
filter
p rogr am
hold
sys t em f an
LCDDisplay:Shows
Time,Day,Temperature,
ProgramNumber,and
otherfeatureinformation
asrequired.
L
Backlightkey
BatteryCompartment:
Frontaccessallows
easyinsertionoftwo
AA1.5Vbatteries.
UpandDownKey:Keyfor
changingtheTemperature
setting.Alsousedforincreasing
anddecreasingselectionsinthe
Time,Program,andSpan
functions.
/re tur n
FanSwitch:Fan
switchforAutomatic
orContinuousfan
operation.
SystemSwitch:
Selectorswitchfor
Heat,Cool,andOff.
Day/TimeKey:
Usedforentering
theClocksetting
mode.Usewiththe
UpandDownkeys
tosetthetimeandday.
FilterKey:Resets
filterchange
countertozero.
ProgramKey:Used
forenteringandmodifying
Programs.UsewiththeUp
andDownkeystoset
timesandtemperatures.
PresswheninClocksetting
modetoselectbetween12
and24hourclockmodes.
Hold/ReturnKey:Usedfor
settingapermanent(vacation)
hold,andforreturningtothe
normaldisplayfromDay&
Timesetting,Programming,or
Spansettingmodes.
FrontDoor:
Batterycover
Openwithone
fingerfromtop.
FrontDoor: CoverkeysOpenwith onefingerfromleftorright.
OPERATION
SettingDayandTime
Ÿ The LCD will show this information when
batteries are first installed. The temperature will
updateafterafewseconds.
Ÿ During time and day setting mode, the
temperatureandprogramdisplayswillgoblank.
ŸExamples:SettheThermostattothecurrenttimeof2:16pmonSaturday.
RefertotheStepsbelow.
STEP1:
Ÿ Press to enter time and day setting mode. The
current hour and the AM/PM indicator will be
flashing.
ŸPressupordowntochangetheHourupordown
tothecurrenthour.
NotetheAM/PMindicator,asthedisplaywillchangeat12AMand12PM.
STEP2:
Ÿ Press again to change from hour setting to
minutesetting.Thecurrentminutewillbeflashing.
Ÿ Press up or down to change the Minute up or
downtothecurrentminute.
STEP3:
ŸPressagaintochangefromminutesettingtoday
setting.Thecurrentdayswillbeflashing.
ŸPressupordowntochangetheDayupordown
tothecurrentday.
STEP4:
ŸPressagaintochangebacktothenormaldisplay.
NOTE: You may press /return at any time during Day and Time setting to
returntothenormaldisplay.
12Hr./ 24Hr. TimeFormat
Yourthermostatissetfromthefactoryinnormal12(AM/PM)timeformat.Tochangeto
24 hour (military) time, press during time and day setting mode to
toggle betweenthe 12 hour and24hour formats. The AM/ PM indicatorwillnot be
displayed in24hourmode.Boththecurrenttimeandall programswillautomatically
changetotheselectedformat.
PROGRAMMING
Thefollowingtimeandtemperaturesettingsarepreprogrammedintothethermostat:
TemperatureinF˚(C˚)
ProgramNumber Time Heat Cool
1 6:00am 68˚F(20˚C) 78˚F(26˚C)
2 8:00am 60˚F(16˚C) 85˚F(29˚C)
3 4:00pm 68˚F(20˚C) 78˚F(26˚C)
4 10:00pm 60˚F(16˚C) 82˚F(28˚C)
ŸAll7daysoftheweekhavethesamedefaultprograms.
PersonalProgramSchedule
ŸYoucanrevisethefactoryprogramstomatchyourownschedule.UsethisPersonal
Program Schedule to determine which times and temperature settings match your
comfortandenergysavingrequirements.Useapencilsoyoucanreviseyourrecords
eachtimeyouchangeyourprogramsettings.
Heating
Day Program1 Program2 Program3 Program4
Monday –
Friday
Time
Temp
Time
Temp
Time
Temp
Time
Temp
Saturday –
Sunday
Time
Temp
Time
Temp
Time
Temp
Time
Temp
Cooling
Day Program1 Program2 Program3 Program4
Monday –
Friday
Time
Temp
Time
Temp
Time
Temp
Time
Temp
Saturday –
Sunday
Time
Temp
Time
Temp
Time
Temp
Time
Temp
RevisingPrograms
ŸFamiliarizeyourselfwithmanuallychangingprograms,sothatyoucaneasilymodify
the programs asyourcomfortneedschange.Followthe stepsbelow to change the
programtimesandtemperature.
NOTE:
1)Theprogramtimecanbesetin10minuteincrements.
2)Theprogramtemperaturecanbesetinincrementsof1˚F(1˚C).
3) After15seconds without akeypress,thethermostat willreturnto normaldisplay
mode.
4)Whensettingtheprogramtime,notetheAM/PMindicator.
STEP1:
ŸSlidetheSystemSwitchtotheHEATorCOOLpositiontoprogramthe
correspondingsystem.
NOTE:iftheSystemSwitchisintheoffposition,
thelastpositionusedwillbeprogrammed.
STEP2:
ŸPresstoenterprogrammode.HEATorCOOLwillbedisplayedonthe
LCD.
STEP3:
ŸTheProgramhourandAMorPMindicatorare
flashing.Presstochangethehour.
STEP4:
ŸPressagaintochangetotheminuteposition.The
currentminutewillbeflashing.
ŸPresstochangetheminute.
STEP5:
Ÿ Press again to change to the program temperature. The
currentprogramwillbeflashing.
ŸPresstochangethetemperature.
STEP6:
ŸPressagaintomovetothenextprogramnumber.
ŸRepeatStep3through5tochangetheremainingWeekdayand
Weekendprograms.(Thereareatotalof8programs)
ŸAftercyclingthroughall8programs,pressagaintoreturnthedisplayto
normal.
ŸPressatanytimetoexittheprogramMode.
Reviewing Programs
To review your program settings, press repeatedlytocyclethrough
theprograms.Youcanalsomakechangesatanytime.
SystemselectorSwitch
The System Selector switch on the front of the thermostat
determines the operating mode of thethermostat. Youmayselect
COOL,OFF,HEAT.
NOTE: Anytime you install or remove the thermostat from the wall plate, slide the
System Selector to the OFF position to prevent the possibility of a rapid system
OnOff.
Fanswitch
TheFan switchshould normally belocated inthe AUTOposition.
The Fan will be turned on along with normal operation of your
system.Inanormalgasoroilfurnace,theFanwillbeturnedonby
yourfurnaceafteritswarmupdelay.Forelectricheat,airconditioning,andheatpump
operation,theFan willturnonwiththesystem.ToruntheFanoncontinuously,slide
theFanswitchtotheONposition.
TemporaryManualOverride
To temporarily change the current set temperature without affecting your
program:
ŸPresstochangetoyourdesiredSetTemperature.
Holdthekeyfor2secondstofastadvancetheSet
Temperature.
ŸPresstoreturntonormalmode,orwait5seconds
forittoreturnautomatically.
ŸThecurrentprogramnumberwillflashtosignifytheTemporaryOverride.
ŸAtthenextprogramchange time, the Temporary Overrideis
cancelled,and the next program temperature becomes the
setpoint temperature.
Ÿ Press to confirm the Temporary
Override,
PermanentOverrideoraDesignatedDayOverride
To hold your Manual Override for vacation or Until a
DesignatedDay.
Ÿ Press to make the current program
temperature the HOLD temperature.
HOLDwillbedisplayedontheLCD,andtheProgramnumber
willdisappear.
ŸFollowtheTemporaryManualOverrideinstructionsabovetochangethe
PermanentManualOverridetemperature.
ŸYoucanconfirmtheheldsettemperaturebypressingforlessthan1
second.
ŸPressagain.Holddaywillbedisplayed
onthelcdandtheclockwilldisappear.
ŸPress Day key to add override days. Press
Programkeytoreduceoverridedays.
Ÿ Follow the Temporary a Designated Day
OverrideinstructionsabovetochangethePermanentManualOverride
temperature.
ToendOverride:
ŸUnder Permanent Override Press hold/return key twice. Under a Designated Day
Overridepress the hold/returnonce.Thethermostatwillreturn
tothecurrentprogram,andtheHOLDdisplaywillbecanceled.
FilterChangeIndicator
Yourthermostatalsokeepsarecordofthenumberofhoursyourfilterhasbeeninuse.
ToMaximizeyoursystem’sperformanceandenergyefficiency,changeorcleanyour
filterregularly.
ŸWhen thetotal system runtime for heat and cool reaches
400 hours, “FILT”willalternate with thecurrent
time on the LCD display to remind you need
cleanorchangeyoursystem’sfilter.”Filt”willcontinuetoflash
untilthecounterissetbacktozero.
ŸPress to reviewtotal filter usage. Thedisplay willblink ”FILT”,then show theFilter
Monitorcounter.After15seconds,thedisplaywillreturntonormalmode
In this example, the counter is at 410 Hours,
26Minutes.
ŸTo reset the Filter Monitor counter, depress Filter key for 3
seconds.thedisplaywillblink,andthecounterwillberesetto
zero.
SPANSetting
Your thermostat is set at the factoryto cycle at 2˚F (1˚C) above and below the set
temperature.(Span=2)Thissettinghasbeendesignedtoprovideacomfortableroom
temperature under most all conditions. However, if you find your system
cyclingtoofastortooslow,thenthe Spancanbeadjusted to modifythe
cycletime.
Ÿ Press and hold BOTH (up and down keys) for
three seconds. The display will flash, and SPAN
willbedisplayedontheLCD.
Ÿ Press to raise the Span to 3. This setting
INCREASEStocycletimebyallowingyoursystem
torunLONGER.
ŸPresstolowertheSpanto1.ThissettingDECREASESthecycletime
bycausingyoursystemtorunSHORTER.
The Span settings remain the same for both HEAT and COOL. The Span can be
changedatanytime,andisindependentofprogramtimesortemperatures.
Backlighting
Your thermostathasanelectroluminescent lamp that backlightsthedisplay for easy
viewinginthedark.
Whenanykeyispressed,thedisplayisilluminated.
Thedisplay willremainilluminated for 8 seconds after thelast keyis pressed. This
allowsthelighttostayonifyouneedtooperateseveralkeys.
Note: If the thermostat is in Low Battery warning condit ion, the backlight will not
operate.Replacewith2newAAalkalinebatteriestorestoretheBacklightfunction.
LowBatteryWarning
Your thermostat has a twostage lower battery warning system.
Whenthebatteriesare first detectedtobeweak,thefirststage
lowbattery warning is indicated by “BATT” flashing onthe LCD
display. At your earliest convenience, you need to replace the
batterieswith2newAAalkalinebatteries.
Whenthe batteries become too weak for normal operation, the
thermostat enters the second stage low battery warning which
shuts down the thermostat. In this condition, “BATT” flashes
aloneonthedisplay,andthethermostatwillturnyoursystemoff.
Yoursystemwillremainshutoffuntilthebatteriesarereplaced.
Note:Thethermostatwillstillkeepthec urrentSetTemperatureandFilterruntimein
memoryuntilnewbatteriesareinstalled. Afterconfirmingthatnewbatterieshav ebeen
inserted,thethermostatwillreturntonormaloperation.
AutoRecovery
Auto Recovery calculates how early to turn you system back on, so that the room
temperature is already comfortable by the start of the comfort temperature program
period.AutoRecoverywork’sinbothHeatandCoolmodes.
ŸWhenthethermostatisinAutoRecoverymode,thedisplaywill
alternate“RECO”withtime,andtheprogramindicatorwillflash.
ŸAutoRecoverycanbedisabledbyslidingtheRecoveryswitch
onthecircuitboardtodisable.
ŸAutoRecoverywillnotoperateifPermanentholdorTemporary
holdisinoperation.
ŸAuto Recovery can be canceled manually if Hold/RETURN is pressed during the
recoveryprocess.
ŸAutoRecoverywillbecanceledandchangetonextperiod.
ErrorMode
If the thermostat is unable to control your system due to an
unexpectedbatteryproblem,thethermostatwillenterErrorMode.
In this condition, the thermostat flashes “E1”or “E2”on the LCD
display, and shuts off your system. To correct this problem,
replacethebatterieswith2newAAalkalinebatteries,evenifyou
haverecentlyreplacedthem.Movethebatteryoutholdanykeythenplacethebattery
again.Youwillneedtoreprogramyourthermostatandconfirmnormaloperation.
IfErrorModereturns,pleasecallusforfurtherinformation.
Lcddisplay information Lcddisplay information
E1 SensorError E2 Systemswitch
AutoCutOff
Your thermostat will automaticallycutoffin Heatmodeifthe roomtemperature rises
above95˚F(35˚C).ItwillcutoffinCoolmodeiftheroomtemperaturedropsbelow45˚F
(7˚C).
Note: that if yoursyst em has malfunctioned and no longer responds to thermostat
controls,theAutoCutOffwillhavenoeffect.
day/time
day/time
hold
/return
heatoff
cool
system
p ro gr am
day/time
day/time
da y/tim e
program
p ro gr am
p ro gr am
heat
off
cool
system
on
auto
fan
hold
/return
filter
p ro gr am
p r o g r a m
M
H
program
hold
hold
/return
hold
/return
hold
/return
hold
/return
filter
Vue de la page 0
1 2

Résumé du contenu

Page 1 - PROGRAMMABLETHERMOSTAT

day/timeprogramPROGRAMMABLETHERMOSTATOwnersManualModel:CP1819LCongratulations!Your new thermostat will provide years of reliable se

Page 2 - INSTALLATION

SelectorSwitchesInorderforthisthermostattocontrolyoursystem,thesystemtypemustbespecifiedby the selectorswitches on the printed

Commentaires sur ces manuels

Pas de commentaire